Product Features
·High-hardness contact tip with a service life of over 10 million cycles
·The probe main body supports output via the RS485 communication interface
·Measured values can be displayed in real time when equipped with an amplifier
·Strip-shaped displacement indicator lights for more intuitive status display
·Supports the over-range alarm function
·The probe main body supports output via the RS485 communication interface
·Measured values can be displayed in real time when equipped with an amplifier
·Strip-shaped displacement indicator lights for more intuitive status display
·Supports the over-range alarm function
Product Parameters
| model | HK-L12 | HK-L25 | |
| measuring range | 0mm~12mm | 0mm~25mm | |
| display resolution | 1um | 3um | |
| response time | 0.1um | 1um | |
| measuring force | <1.5N | ||
| supply voltage | DC 24V | ||
| environmental resistance | levels of protection | IP50 | |
| ambient temperature | Temperatures range from-20°C to +55°C, with no freezing occurrence. | ||
| ambient humidity | 35–85% RH, no condensation | ||
| antiknock characteristics | Acceleration: 500 m/s², applied five times in each direction (X, Y, Z). | ||
| vibration resistance | 10 to 55 Hz, composite amplitude of 1.5 mm, with 2-hour measurements along the X, Y, and Z axes | ||
| Shell Material | sensing head: stainless steel; rubber sheath: Viton; mounting bracket: stainless steel; stator: super steel | ||
| outline dimension | 270mm(H)*100mm(W) | ||
| Product Weight | 150g | ||
| accessories of a product | not have | ||
Product Dimensions
Input and output circuit diagram