Product Features
·Economical model with Z-axis accuracy up to 0.02 mm
·Stable and fast, with a single sampling time of approximately 2 seconds
·Open and accessible: open SDK, compatible with multiple platforms, with proprietary core algorithms
·Flexible and user-friendly, shock-resistant, waterproof, portable and lightweight, specially designed for industrial application scenarios
·Stable and fast, with a single sampling time of approximately 2 seconds
·Open and accessible: open SDK, compatible with multiple platforms, with proprietary core algorithms
·Flexible and user-friendly, shock-resistant, waterproof, portable and lightweight, specially designed for industrial application scenarios
Product Parameters
| model | HV3D0700-R2 | |
| Working Distance | 250mm~1800mm | |
| resolution ratio | 2.3MP | |
| Ambient Light Immunity | 3000Lux | |
| communication interface | Gigabit Ethernet Interface | |
| 3D point cloud acquisition time (s) | Monocular mode: 1.2s per frame; Binocular mode: 1.9s per frame | |
| At 300 mm | depth of field | 100mm |
| FOV | At 250 mm: 160×106 mm; at 350 mm: 237×150 mm | |
| XY resolution | 0.16mm | |
| Z-axis Measurement Accuracy (1) | 0.02mm | |
| Z-axis Repeatability (2) | 0.04mm | |
| at 1650 mm | Depth of Field | 300mm |
| FOV | At 1500 mm: 724×490 mm; at 1800 mm: 1095×745 mm | |
| XY resolution | 0.75mm | |
| Z-axis measurement accuracy | 0.42mm | |
| Z-axis Repeatability | 0.62mm | |
| environmental resistance | levels of protection | IP67 |
| ambient temperature | -25°C to +70°C, no freezing | |
| ambient humidity | 35–85% RH, no condensation | |
| antiknock characteristics | Acceleration 500 m/s², 5 times in each direction X/Y/Z | |
| vibration resistance | 10–55 Hz, 1.5 mm amplitude, 2 h each along X/Y/Z | |
| Shell Material | alufer | |
| outline dimension | 336mm(H)*115mm(W)*50mm(D) | |
| Product Weight | 1.8kg | |
| accessories of a product | To purchase lenses, light sources, light source controllers, extension cables, or mounts, select them separately. | |
Note: At the calibrated working distance, a precision-machined metal step gauge is captured 20 times, and the absolute mean of the error between measured and true step height is calculated. At the calibrated working distance, 20 captures are taken and the 2σ value of the step height measurement distribution is calculated. This series of binocular 3D stereo sensors is available with color CCD or mono CCD; the above data was obtained using a color CCD. For any questions, please contact Heinxs sales staff.
Field of view